UGX6,050,000.00 Original price was: UGX6,050,000.00.UGX5,700,000.00Current price is: UGX5,700,000.00.
Item Dimensions LxWxH | 3.46 x 24.25 x 17.24 inches |
Voltage | 240 Volts |
Item Weight | 84.22 Pounds |
Wattage | 2700 watts |
UPC Code | 037332185631 |
UPS Type | On-Line |
Rated input current (Maximum Load) | 14.97A |
Nominal Input Voltage(s) Supported | 200V AC; 208V AC; 220V AC; 230V AC; 240V AC |
UPS Input Connection Type | C20 inlet |
Input Phase | Single-Phase |
Output Volt Amp Capacity (VA) | 3000 |
Output Capacity (kVA) | 3 |
Output Watt Capacity (Watts) | 2700 |
Output kW Capacity (kW) | 2.7 |
Output Capacity Details | DE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 1890 watts for 208/220/230/240V output voltages; Max output is reduced to 2160W at 200V output voltage in all operating modes OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypassed limits). |
Power Factor |
0.9 | |
Crest Factor |
3:1 | |
Nominal Voltage Details | The nominal output voltage is user configured on first power-on |
Frequency Compatibility | 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion |
Frequency Compatibility Details | Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation |
Output Voltage Regulation (Line Mode) | +/- 2% |
Output Voltage Regulation (Economy Line Mode) | +/- 10% |
Output Voltage Regulation (Battery Mode) | +/- 2% |
Included Output Power Cables | Includes 2 C13 to C14 and 1 C19 to C20 power cables |
Load Management Receptacles |
Two switchable 4 outlet load banks (3 C13 and 1 C19 per bank) | |
Output AC Waveform (AC Mode) | Pure Sinewave |
Output AC Waveform (Battery Mode) | Pure Sinewave |
Nominal Output Voltage(s) Supported | 200V; 208V; 220V; 230V; 240V |
Output Receptacles | (8) C13; (2) C19 |
Individually Controllable Load Banks |
Yes |
Battery Type | Valve Regulated Lead Acid (VRLA) |
Full Load Runtime (min.) |
5 min. (2700w) | |
Half Load Runtime (min.) |
13.5 min. (1350w) | |
Expandable Battery Runtime | Supports extended runtime with optional external battery packs |
Expandable Runtime | Yes |
External Battery Pack Compatibility |
BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible) | |
DC System Voltage (VDC) | 72 |
Battery Recharge Rate (Included Batteries) | 3.0 hours from 10% to 90% (typical, full load discharge) |
Battery Access | Front panel battery access door |
Internal UPS Replacement Battery Cartridge | RBC72S |
Battery Replacement Description | Hot-swappable, replaceable batteries |
Voltage Regulation Description | Online, double-conversion power conditioning |
Overvoltage Correction |
2% output voltage regulation during overvoltages to 288 | |
Undervoltage Correction |
2% output voltage regulation during undervoltages to 160V (100% load), 130V (70% load), 100V (30% load) |
Front Panel LCD Display | Interactive front-panel LCD interface reports UPS operating mode, detailed UPS status, and site-power information; LCD interface also enables a variety of advanced UPS setup and configuration options |
Switches | 5 front panel switches: On/Off, Up, Down, and Escape |
Alarm Cancel Operation | The power-fail alarm can be silenced by following on-screen prompts |
Audible Alarm | Audible alarm indicates power failure, low battery, overload, and fault |
LED Indicators | 4 front panel LEDs: AC input (green), AC output (green), Battery (yellow), Fault (red) |
UPS Dataline Suppression Details | Single line dialup/network data line protection included |
EMI / RFI AC Noise Suppression |
Yes | |
AC Suppression Joule Rating |
570 | |
AC Suppression Response Time |
Instantaneous |
Primary Form Factor | Rackmount |
Cooling Method | Fan |
Included Mounting Accessory Description | 4 post installation accessories included |
Installation Form Factors Supported with Included Accessories | 4 post 19-inch rackmount |
Installation Form Factors Supported with Optional Accessories | 2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); Tower ( 2-9USTAND ) |
Minimum Required Rack Depth with External Battery Pack (cm) | 77 |
Minimum Required Rack Depth with External Battery Pack (in.) | 30.25 |
Minimum Required Rack Depth without External Battery Pack (cm) | 70 |
Minimum Required Rack Depth without External Battery Pack (in.) | 27.75 |
Primary UPS Depth (mm) | 616 |
Primary UPS Height (mm) | 88 |
Primary UPS Width (mm) | 438 |
Rack Height | 2U |
Shipping Dimensions (hwd / cm) | 24.00 x 59.99 x 76.00 |
Shipping Weight (kg) | 39.01 |
UPS Housing Material | Metal |
UPS Power Module Dimensions (hwd, cm) | 8.79 x 43.79 x 61.60 |
UPS Power Module Weight (kg) | 31.17 |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius. |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius. |
Relative Humidity | 5 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) |
933 | |
AC Economy Mode BTU / Hr. (Full Load) | 485 |
Battery Mode BTU / Hr. (Full Load) |
1399 | |
AC Mode Efficiency Rating (100% Load) | >90% |
AC Economy Mode Efficiency Rating (100% Load) | >95% |
Audible Noise | <50dB at front side 1M |
Operating Elevation (m) | Up to 3000m |
Network Management Cards | SNMPWEBCARD; WEBCARDLX |
PowerAlert Software | For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert |
Communications Cable | USB and DB9 cabling included |
WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
Network Management Card Description | Network management card optional |
Communications Interface | Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |
Transfer Time |
No transfer time (0 ms.) in online, double-conversion mode; 4 ms. transfer time during economy mode operation | |
Low Voltage Transfer to Battery Power (Setpoint) | 160V (100% load), 140V (66% load), 120V (33% load) |
High Voltage Transfer to Battery Power (Setpoint) | 288V |
Grounding Lug | Back panel grounding lug included |
Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
High Availability UPS Features |
Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic inverter bypass; Expandable battery backup; Hot-swappable batteries; On-Line/Double-Conversion; Remote management; Sine wave output; Surge/noise protection; Zero transfer time | |
Green Energy-Saving Features | High-efficiency economy mode operation; Individually controllable load banks |
UPS Certifications | CE; ENERGY STAR Qualified; Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to EAC (Belarus, Kazakhstan, Russia); Tested to SASO (Saudi Arabia); Tested to UL1778 (USA) |
Certification Details | Meets EMI approvals IEC62040-2:2006; FCC Part 15 |